www.
ac-fix.
com
TB8008(EN) V7 2011-05-10
8008 – CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN.
Function:
Circulation units for solar thermal systems are used in the
primary circuit of solar heating systems to control the
temperature...
More
www.
ac-fix.
com
TB8008(EN) V7 2011-05-10
8008 – CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN.
Function:
Circulation units for solar thermal systems are used in the
primary circuit of solar heating systems to control the
temperature of the hot water storage.
The unit contains
functional and safety devices for an optimized circuit control.
It’s a compact and integral solution and properly isolated that
allows to recover the thermal energy of the sun until the
storage.
Technical characteristics:
Medium: water – glycol solution (max.
50%)
Max.
working temperature: 180ºC
Max.
working pressure: 10bar
Temp.
range of safety valve: -30ºC to 160ºC
Setting pressure of safety valve: 6bar
Min.
open pressure of check valve: 2kPa
Flow rate range: 1 to 13 l/m
Max.
temperature of flow meter: 120ºC
Pressure range of pressure gauge: 0 to 6bar
Temperature range of flow and return temperature gauges: 0 to
160ºC
In-Out connections size: F 3/4”
Co
Less